Product Description

We feel proud to introduce ourselves as one of the leading organizations in this domain, engaged in manufacturing and exporting optimum quality Single Channel Gas Monitor. Fully based on advanced technology, it is widely used for monitoring combustible and toxic gases in many industries. This equipment is manufactured by our professionals using modern technological tools and high grade components. In addition, Single Channel Gas Monitor is available for our patrons as per their specific demands at affordable rates.

Features:

  • Full maintenance functions with very easy zero and span adjustment.
  • Proven reliability with years of experience - COSMOS gas senaors have a small zero drift, a small sensitivity decrease, and a long life.
  • Zero suppression function cancels slight fluctuations of the reading due to environmental change.
  • Compact Indicator / Alarm unit - W113xH204xD71.5mm, approx. 1.5kg.
  • Battery provides backup power in case of a power failure, allowing continuous monitoring over 60 minutes after the failure. (Option)

Type Explanation:

  • C For combustible gas
  • H For combustible gas (High sensitive)
  • D For toxic gas/semiconductor manufacturing gas
  • S For oxygen

Technical Data:

Model

NV-100C

NV-100H

NV-100D

NV-100S

Detection Principle

Catalytic combustion

Hot-Wire Semiconductor

Controlled Potential Electrolysis

Galvanic Cell

Gas Detected

Combustible gas ( L.PG, Methane, .etc.)

Combustible gas ( L.PG, Methane, .etc.)

Toxic gas/ Semiconductor manufacturing gas

Oxygen (deficiency/leakage)

Detection Range

0-100%LEL

As per specification

As per specification

0-25vol% (deficiency)
0-50vol% (leakage)

Concentration Indicator

LCD bar-graph meter with backlight

LCD bar-graph meter with backlight

LCD bar-graph meter with backlight

LCD bar-graph meter with backlight

Alarm Accuracy

±25% of an alarm set value

±25% of an alarm set value

±30% of an alarm set value

±1.0vol% of an alarm set value
(conferms to JIS T 8201)

Operating Temperature Range

0oC to 40oC

0oC to 40oC

0oC to 40oC

0oC to 40oC

Power Source/Power Consumption

100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added

100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added

100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added

100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added

Alarm Indication

Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing

Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing

Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing

Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing

Trouble Indication

Power source lamp lights up in orange

Power source lamp lights up in orange

Power source lamp lights up in orange

Power source lamp lights up in orange

External Output

Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load)

Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load)

Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load)

Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load)

Dimensions

Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg
With backup power source : W113xH234xD110mm, Approx. 3kg

Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg
With backup power source : W113xH234xD110mm, Approx. 3kg

Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg
With backup power source : W113xH234xD110mm, Approx. 3kg

Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg
With backup power source : W113xH234xD110mm, Approx. 3kg

 